Prize37 Chapter 6, Exercise 2 Energy for a balanced pair of caissons Task A pair of balanced caissons of 200 tonnes each lifts 12 metres, with the pair balanced to within 3 per cent. Work out the energy for a single lift of one caisson with no counterweight, and for the imbalance case, in kilowatt-hours. Explain why the second figure is so much smaller. (assumed figures throughout) Code (run with Python) g = 9.81 mass = 200000 # kg per caisson (200 tonnes) height = 12 # metres single = mass * g * height / 3.6e6 imbalance = 0.03 * single print("no counterweight (kWh):", round(single, 1)) print("balanced to within 3 % (kWh):", round(imbalance, 2)) Output (exactly as printed) no counterweight (kWh): 6.5 balanced to within 3 % (kWh): 0.2 Answer Raising 200 tonnes by 12 metres with no counterweight costs m g h = 200000 x 9.81 x 12 joules, which is about 6.5 kWh. With the pair balanced to within 3 per cent only 3 per cent of that, about 0.2 kWh, is needed to make up the difference between the two sides. The reason is that a balanced pair behaves like a seesaw: when one caisson goes up, the other comes down and gives back almost all the energy the first one needed, so the drive pays only for the imbalance and the friction (check).