Robotics Fundamentals 1, Chapter 10: Challenge 1 solution (power budget and fuse choice) Formulas: rail load from the pack: I(pack) = V(rail) x I(rail) / ( eta x V(pack) ), eta = 0.90 for the buck runtime t = 0.8 x V x C / P ; fuse = 125 % to 150 % of the normal (largest sustained) current, below the wire rating, close to the battery wire drop V = I x R(per metre) x ( 2 x one-way length ) ; C-rate = I / C ; sag = I x R(internal) linear regulator: I(pack) = I(rail), heat = ( V(in) - V(out) ) x I(rail) Pack: 3S LiPo 11.1 V, 2200 mAh, R(internal) = 0.090 ohm. Motors at the pack: 0.9 A average, 1.6 A worst working, 7.5 A stall, each. (a) The 5 V rail: average 0.25 + 0.12 + 0.10 = 0.47 A peak working 0.35 + 0.12 + 0.70 = 1.17 A From the pack through the 90 % buck: average 5 x 0.47 / 0.90 = 2.611 W, 2.611 / 11.1 = 0.2352 A peak 5 x 1.17 / 0.90 = 6.500 W, 6.500 / 11.1 = 0.5856 A (b) Total pack current: average 2 x 0.9 + 0.2352 = 1.8 + 0.2352 = 2.035 A worst working 2 x 1.6 + 0.5856 = 3.2 + 0.5856 = 3.786 A stall 2 x 7.5 + 0.5856 = 15.0 + 0.5856 = 15.586 A Average power P = 11.1 x 2.0352 = 22.59 W. (c) Energy E = 11.1 x 2.2 = 24.42 Wh, usable 0.8 x 24.42 = 19.54 Wh. Runtime t = 19.536 / 22.59 = 0.865 h = 51.9 minutes. (d) Fuse: 1.25 x 3.786 = 4.73 A to 1.50 x 3.786 = 5.68 A. A 5 A fuse is inside the range (5 / 3.786 = 132 %). Wire must be rated ABOVE the fuse: 24 AWG (3.5 A) is not acceptable; 22 AWG (7 A) and 20 AWG (11 A) are. Voltage drop at 3.786 A for 0.4 m each way (0.8 m round trip): 22 AWG: R = 0.053 x 0.8 = 0.0424 ohm, V = 3.786 x 0.0424 = 0.161 V (1.4 % of 11.1 V) 20 AWG: R = 0.0333 x 0.8 = 0.02664 ohm, V = 3.786 x 0.02664 = 0.101 V (0.9 % of 11.1 V) Choose 20 AWG: the lower drop and the larger margin below its 11 A rating (a stall of 15.6 A is three times the 5 A fuse: it opens in about a second or less, read its curve, which is the intended protection). Check the placement: the fuse goes in the positive lead next to the pack, and its voltage rating must be at least 12.6 V (the full pack). (e) C-rate at stall: 15.586 / 2.2 = 7.08C (a 20C pack copes). Voltage sag at stall: 15.586 x 0.090 = 1.40 V: the pack's 11.1 V nominal gives about 9.70 V at the motors (a 12.6 % drop); the bulk capacitor at the driver and the stall rule limit how long that lasts. (f) Linear regulator for the 5 V rail from 11.1 V: average pack power = 11.1 x 0.47 = 5.217 W (heat in the regulator = ( 11.1 - 5.0 ) x 0.47 = 2.867 W) buck: 2.611 W peak pack power = 11.1 x 1.17 = 12.99 W (heat = 6.1 x 1.17 = 7.14 W: far too hot for a bare regulator) buck: 6.500 W With the linear regulator the average power is 22.59 - 2.611 + 5.217 = 25.20 W and the runtime falls to 19.536 / 25.20 = 0.775 h = 46.5 minutes (against 51.9 min with the buck). The buck saves 2.6 W on the average and avoids a regulator that dissipates 7 W at the servo's peak: use the buck.